- トノイテ、オ、、ソケヤ、マ、ウ、ホソァ、ヌ、ケ。」
- コス、オ、、ソケヤ、マ、ウ、ホソァ、ヌ、ケ。」
フワシ。~
#contents
*ウオヘラ [#md4cce82]
HPE(HP)、ホSmartArray、ホエノヘ・ト。シ・、ヒエリ、ケ、ニウニ。ヲチ犲シス遑」~
*ニウニシス [#i4960d92]
**ESXi [#id7d6bfb]
ESXi、リニウニ、ケ、コン、ヒ、マ。「・ム・テ・ア。シ・ク、ホニシ熙キ、ニVIB・ユ・。・、・、ホ・、・・ケ・ネ。シ・、ケヤ、ヲ。」
***エトカュセハ [#dbc89bea]
|VMware vSphere 6.7|ESXi 6.7u3|VMware ESXi, 6.7.0, 15160138|
***・ム・テ・ア。シ・クヌロノロクオ [#ieb91e32]
|HPE ESXi・譯シ・ニ・」・・ニ・」・ェ・ユ・鬣、・・ミ・・ノ・ for VMware vSphere 6.7 - 3.2.0(20 4 2018)|esxi6.7-util-bundle-3.2.0-12.zip|[[・タ・ヲ・・。シ・ノ:https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX-702d3c7d8c4546a3b27d1458b5#tab3]]|
***ニウニシス [#p1203934]
-1. ・タ・ヲ・・。シ・ノ、キ、ソ・ム・テ・ア。シ・ク、ホーオスフ、イス、キ、゙、ケ
unzip esxi6.7-util-bundle-3.2.0-12.zip
-2. イナ、キ、ソ・「。シ・ォ・、・ヨ、ォ、鬘「エノヘ・ト。シ・、ホVIB・ユ・。・、・、コカネホホー隍ヒ・ウ・ヤ。シ、キ、゙、ケ
cp ssacli-3.25.4.0-6.5.0.vib /tmp
-3. ーハイシ、ホ・ウ・゙・・ノ、ヌVIB・ユ・。・、・、・、・・ケ・ネ。シ・、キ、゙、ケ
esxcli software vib install -v /tmp/ssacli-3.25.4.0-6.5.0.vib
Installation Result
Message: The update completed successfully, but the system needs to be rebooted for the changes to be effective.
Reboot Required: true
VIBs Installed: HPE_bootbank_ssacli_3.25.4.0-6.5.0.4240417
VIBs Removed:
VIBs Skipped:
-4. ・、・・ケ・ネ。シ・キイフ、ウホヌァ、キ、゙、ケ
esxcli software vib list | grep ssacli
~
ーハイシ、ホキイフ、ャノスシィ、オ、、、ウ、ネ、ウホヌァ、キ、゙、ケ
ssacli。。 3.25.4.0-6.5.0.4240417。。 HPE。。 PartnerSupported 2021-01-1
-5. オッニーサ、ヒ・キ・・ワ・・テ・ッ、トノイテ、ケ、ス靉、タ゚ト熙キ、゙、ケ
vi /etc/rc.local.d/local.sh
~
ヒネ、ヒーハイシ、トノオュ、キ、゙、ケ
# HP Attay cli
test -f /opt/smartstorageadmin/ssacli/bin/ssacli && ln -s /opt/smartstorageadmin/ssacli/bin/ssacli ssacli
-6. ESXi、コニオッニー、キ、゙、ケ
*チ犲シス [#ef516fb1]
**セハノスシィ [#h464762e]
***タ゚トセツヨ、ホノスシィ。ハチエHBA。ヒ [#gb7d4fe6]
-スシー
ssacli ctrl all show config
~
-スミホマキイフ。ハタオセサ。ヒ
Smart Array P410 in Slot 20 (sn: xxxxxxxxxxx)
Port Name: 1I
Port Name: 2I
Array A (SATA, Unused Space: 0 MB)
logicaldrive 1 (3.64 TB, RAID 1+0, OK)
physicaldrive 1I:0:1 (port 1I:box 0:bay 1, SATA HDD, 2 TB, OK)
physicaldrive 1I:0:2 (port 1I:box 0:bay 2, SATA HDD, 2 TB, OK)
physicaldrive 1I:0:3 (port 1I:box 0:bay 3, SATA HDD, 2 TB, OK)
physicaldrive 1I:0:4 (port 1I:box 0:bay 4, SATA HDD, 2 TB, OK)
SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 50014380168595AF)
~
-スミホマキイフ。ハ・ヌ・」・ケ・ックホセ羹。ヒ
Smart Array P410 in Slot 20 (sn: xxxxxxxxxxx)
Port Name: 1I
Port Name: 2I
Array A (SATA,
logicaldrive 1 (3.64 TB, RAID 1+0, Interim Recovery Mode)
physicaldrive 1I:0:1 (port 1I:box 0:bay 1, SATA HDD, 2 TB, OK)
physicaldrive 1I:0:2 (port 1I:box 0:bay 2, SATA HDD, 2 TB, OK)
physicaldrive 1I:0:3 (port 1I:box 0:bay 3, SATA HDD, 2 TB, Failed)
physicaldrive 1I:0:4 (port 1I:box 0:bay 4, SATA HDD, 2 TB, OK)
SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 50014380168595AF)
~
-スミホマキイフ。ハコニケステロサ。ヒ
Smart Array P410 in Slot 20 (sn: xxxxxxxxxxx)
Port Name: 1I
Port Name: 2I
Array A (SATA, Unused Space: 0 MB)
logicaldrive 1 (3.64 TB, RAID 1+0, Recovering, 1% complete)
physicaldrive 1I:0:1 (port 1I:box 0:bay 1, SATA HDD, 2 TB, OK)
physicaldrive 1I:0:2 (port 1I:box 0:bay 2, SATA HDD, 2 TB, OK)
physicaldrive 1I:0:3 (port 1I:box 0:bay 3, SATA HDD, 2 TB, Rebuilding)
physicaldrive 1I:0:4 (port 1I:box 0:bay 4, SATA HDD, 2 TB, OK)
SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 50014380168595AF)
***・ウ・・ネ・。シ・鬢ホセツヨ、ノスシィ [#cb57a7c8]
-スシー
ssacli ctrl all show status
~
-スミホマキイフ
Smart Array P410 in Slot 20
Controller Status: OK
Cache Status: OK
Battery/Capacitor Status: OK
***・ウ・・ネ・。シ・鬢ホセワコル、ノスシィ [#p89acff7]
-スシー
ssacli ctrl all show detail
~
-スミホマキイフ
Smart Array P410 in Slot 20
Bus Interface: PCI
Slot: 20
Serial Number: xxxxxxxxxxxx
Cache Serial Number: xxxxxxxxxxxx
Controller Status: OK
Hardware Revision: C
Firmware Version: 3.66-0
Rebuild Priority: Medium
Expand Priority: Medium
Surface Scan Delay: 15 secs
Surface Scan Mode: Idle
Parallel Surface Scan Supported: No
Queue Depth: Automatic
Monitor and Performance Delay: 60 min
Elevator Sort: Enabled
Degraded Performance Optimization: Disabled
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: 0 secs
Cache Board Present: True
Cache Status: OK
Cache Ratio: 25% Read / 75% Write
Drive Write Cache: Disabled
Total Cache Size: 1.0
Total Cache Memory Available: 0.9
No-Battery Write Cache: Disabled
Cache Backup Power Source: Capacitors
Battery/Capacitor Count: 1
Battery/Capacitor Status: OK
SATA NCQ Supported: True
Number of Ports: 2 Internal only
Encryption: Not Set
Driver Name: nhpsa
Driver Version: 2.0.30-1OEM
PCI Address (Domain:Bus:Device.Function): 0000:07:00.0
Port Max Phy Rate Limiting Supported: False
Sanitize Erase Supported: False
Primary Boot Volume: None
Secondary Boot Volume: None
***ハェヘ・ヌ・」・ケ・ッ、ホセツヨ、ノスシィ [#ob2adea4]
-スシー
ssacli ctrl slot=[HBA No.] pd all show detail
~
-スミホマキイフ
Smart Array P410 in Slot 20
Array A
physicaldrive 1I:0:1
Port: 1I
Box: 0
Bay: 1
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 2 TB
Drive exposed to OS: False
Logical/Physical Block Size: 512/512
Rotational Speed: 7200
Firmware Revision: MX4OABB0
Serial Number: xxxxxxxxxxxx
WWID: 30014380168595A0
Model: ATA TOSHIBA DT01ACA2
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 30
Maximum Temperature (C): 58
PHY Count: 1
PHY Transfer Rate: 3.0Gbps
Sanitize Erase Supported: False
Shingled Magnetic Recording Support: None
physicaldrive 1I:0:2
Port: 1I
Box: 0
Bay: 2
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 2 TB
Drive exposed to OS: False
Logical/Physical Block Size: 512/512
Rotational Speed: 7200
Firmware Revision: MX4OABB0
Serial Number: xxxxxxxxxxxx
WWID: 30014380168595A1
Model: ATA TOSHIBA DT01ACA2
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 30
Maximum Temperature (C): 55
PHY Count: 1
PHY Transfer Rate: 3.0Gbps
Sanitize Erase Supported: False
Shingled Magnetic Recording Support: None
physicaldrive 1I:0:3
Port: 1I
Box: 0
Bay: 3
Status: Rebuilding
Drive Type: Data Drive
Interface Type: SATA
Size: 2 TB
Drive exposed to OS: False
Logical/Physical Block Size: 512/512
Rotational Speed: 7200
Firmware Revision: MX4OABB0
Serial Number: xxxxxxxxxxxx
WWID: 30014380168595A2
Model: ATA TOSHIBA DT01ACA2
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 31
Maximum Temperature (C): 63
PHY Count: 1
PHY Transfer Rate: 3.0Gbps
Sanitize Erase Supported: False
Shingled Magnetic Recording Support: None
physicaldrive 1I:0:4
Port: 1I
Box: 0
Bay: 4
Status: OK
Drive Type: Data Drive
Interface Type: SATA
Size: 2 TB
Drive exposed to OS: False
Logical/Physical Block Size: 512/512
Rotational Speed: 7200
Firmware Revision: MX4OABB0
Serial Number: xxxxxxxxxxxx
WWID: 30014380168595A3
Model: ATA TOSHIBA DT01ACA2
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 28
Maximum Temperature (C): 43
PHY Count: 1
PHY Transfer Rate: 3.0Gbps
Sanitize Erase Supported: False
Shingled Magnetic Recording Support: None
**チ犲 [#w88089f8]
***・ヌ・」・ケ・ッ、ホク。スミ [#p2767fda]
-スシー
ssacli rescan
~
-スミホマキイフ
スミホマキイフ、マ、「、熙゙、サ、
**マタヘ・ノ・鬣、・ヨチ犲 [#x1cf96b2]
***RAID1・「・・、コタョ [#r8aa7258]
RAID1・「・・、、コタョ、ケ、シス遑」~
-1. ・ノ・鬣、・ヨ、ホウホヌァ
ssacli ctrl all show config
Smart Array P410 in Slot 0 (Embedded) (sn: PACCRID11310DMX)
Unassigned
physicaldrive 1I:0:3 (port 1I:box 0:bay 3, SATA SSD, 1 TB, OK)
physicaldrive 1I:0:4 (port 1I:box 0:bay 4, SATA SSD, 1 TB, OK)
SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 50014380168595AF)
-2. ・「・・、、ホコタョ
ssacli ctrl slot=0 create type=ld drives=1I:0:3,1I:0:4 raid=1 forced
-3. キイフ、ホウホヌァ
ssacli ctrl all show config
Smart Array P410 in Slot 0 (Embedded) (sn: PACCRID11310DMX)
Array B (Solid State SATA, Unused Space: 0 MB)
logicaldrive 2 (931.48 GB, RAID 1, OK)
physicaldrive 1I:0:3 (port 1I:box 0:bay 3, SATA SSD, 1 TB, OK)
physicaldrive 1I:0:4 (port 1I:box 0:bay 4, SATA SSD, 1 TB, OK)
SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 50014380168595AF)
***RAID・「・・、コス [#p63c8905]
・「・・、、コス、ケ、シス遑」
-1. マタヘ・ノ・鬣、・ヨ、ホウホヌァ~
コス、ケ、マタヘ・ノ・鬣、・ヨ、ウホヌァ、ケ、。」
ssacli ctrl all show config
Smart Array P410 in Slot 0 (Embedded) (sn: PACCRID11310DMX)
Port Name: 1I
Port Name: 2I
Array A (SATA,
logicaldrive 1 (5.46 TB, RAID 1+0, Interim Recovery Mode)
physicaldrive 1I:0:1 (port 1I:box 0:bay 1, SATA HDD, 2 TB, OK)
physicaldrive 1I:0:2 (port 1I:box 0:bay 2, SATA HDD, 2 TB, OK)
physicaldrive 2I:0:5 (port 2I:box 0:bay 5, SATA HDD, 2 TB, OK)
physicaldrive 2I:0:6 (port 2I:box 0:bay 6, SATA HDD, 2 TB, OK)
physicaldrive 2I:0:7 (port 2I:box 0:bay 7, SATA HDD, 2 TB, OK)
physicaldrive 2I:0:8 (port 2I:box 0:bay 8, SATA HDD, 0 GB, Failed)
Array B (Solid State SATA, Unused Space: 0 MB)
logicaldrive 2 (931.48 GB, RAID 1, OK)
physicaldrive 1I:0:3 (port 1I:box 0:bay 3, SATA SSD, 1 TB, OK)
physicaldrive 1I:0:4 (port 1I:box 0:bay 4, SATA SSD, 1 TB, OK)
SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 50014380168595AF)
-2. マタヘ・ノ・鬣、・ヨ、ホコス。ハSlot 0 logicaldrive 1。ヒ~
マタヘ・ノ・鬣、・ヨ、サリト熙キ。「コス、ケヤ、ヲ。」~
ssacli ctrl slot=0 ld 1 delete forced
Warning: Deleting an array can cause other array letters to become renamed.
E.g. Deleting array A from arrays A,B,C will result in two remaining
arrays A,B ... not B,C
-3. キイフ、ホウホヌァ~
ホムヘ・ノ・鬣、・ヨ。ハSlot 0 logicaldrive 1。ヒ、ャコス、オ、。「ケスタョ、キ、ニ、、、ソハェヘ・ヌ・」・ケ・ッ、ャ Unassigned 、ネ、キ、ニノスシィ、オ、、。」~
ssacli ctrl all show config
Smart Array P410 in Slot 0 (Embedded) (sn: PACCRID11310DMX)
Port Name: 1I
Port Name: 2I
Array A (Solid State SATA, Unused Space: 0 MB)
logicaldrive 2 (931.48 GB, RAID 1, OK)
physicaldrive 1I:0:3 (port 1I:box 0:bay 3, SATA SSD, 1 TB, OK)
physicaldrive 1I:0:4 (port 1I:box 0:bay 4, SATA SSD, 1 TB, OK)
Unassigned
physicaldrive 1I:0:1 (port 1I:box 0:bay 1, SATA HDD, 2 TB, OK)
physicaldrive 1I:0:2 (port 1I:box 0:bay 2, SATA HDD, 2 TB, OK)
physicaldrive 2I:0:5 (port 2I:box 0:bay 5, SATA HDD, 2 TB, OK)
physicaldrive 2I:0:6 (port 2I:box 0:bay 6, SATA HDD, 2 TB, OK)
physicaldrive 2I:0:7 (port 2I:box 0:bay 7, SATA HDD, 2 TB, OK)
SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 50014380168595AF)
*Tips [#lb016187]
**・ィ・鬘シツミア [#c9cee323]
***Warning: The command was not executed. When using SSACLI with esxcli you must supply the "forced" flag to complete the operation. [#k4a70c80]
ESXi6キマーハケ゚、ヌ、マ。「ーノ・ウ・゙・・ノ、マ "forced" ・ユ・鬣ー、、ト、ア、ニシツケヤ、ケ、ノャヘラ、ャ、「、。」
-create
ssacli ctrl slot=0 create type=ld drives=1I:0:3,1I:0:4 raid=1 forced
*サイケヘ [#z217b69a]
[[Manage HPE Smart Array in VMware ESXi 6.7:https://blog.ndk.name/manage-hpe-smart-array-in-vmware-esxi/]]